# LED Hardware Communication Protocol
|
||
|
||
## Overview
|
||
|
||
UDP-based bidirectional protocol for communication between desktop application and ambient light hardware boards. The protocol supports LED color data transmission, device health monitoring, and remote control capabilities.
|
||
|
||
## Connection
|
||
|
||
- **Protocol**: UDP
|
||
- **Port**: 23042
|
||
- **Discovery**: mDNS (`_ambient_light._udp.local.`)
|
||
- **Example Board**: `192.168.31.206:23042`
|
||
|
||
## mDNS Service Discovery
|
||
|
||
### Service Registration (Hardware Side)
|
||
|
||
Hardware boards must register the following mDNS service:
|
||
|
||
- **Service Type**: `_ambient_light._udp.local.`
|
||
- **Port**: 23042
|
||
- **TXT Records**: Optional, can include device information
|
||
|
||
### Service Discovery (Desktop Side)
|
||
|
||
Desktop application continuously browses for `_ambient_light._udp.local.` services and automatically connects to discovered devices.
|
||
|
||
## Protocol Messages
|
||
|
||
The protocol uses different message headers to distinguish message types:
|
||
|
||
| Header | Direction | Purpose | Format |
|
||
|--------|-----------|---------|---------|
|
||
| 0x01 | Desktop → Hardware | Ping (Health Check) | `[0x01]` |
|
||
| 0x01 | Hardware → Desktop | Pong (Health Response) | `[0x01]` |
|
||
| 0x02 | Desktop → Hardware | LED Color Data | `[0x02][Offset_H][Offset_L][Color_Data...]` |
|
||
| 0x03 | Hardware → Desktop | Display Brightness Control | `[0x03][Display_Index][Brightness]` |
|
||
| 0x04 | Hardware → Desktop | Volume Control | `[0x04][Volume_Percent]` |
|
||
|
||
## Health Check Protocol (Ping/Pong)
|
||
|
||
### Desktop → Hardware (Ping)
|
||
|
||
```text
|
||
Byte 0: Header (0x01)
|
||
```
|
||
|
||
### Hardware → Desktop (Pong)
|
||
|
||
```text
|
||
Byte 0: Header (0x01)
|
||
```
|
||
|
||
**Behavior:**
|
||
|
||
- Desktop sends ping every 1 second to each connected device
|
||
- Hardware must respond with pong within 1 second
|
||
- Timeout or incorrect response triggers reconnection logic
|
||
- After 10 failed attempts, device is marked as disconnected
|
||
|
||
## LED Color Data Protocol
|
||
|
||
### Packet Format
|
||
|
||
```text
|
||
Byte 0: Header (0x02)
|
||
Byte 1: Offset High (upper 8 bits of data byte offset)
|
||
Byte 2: Offset Low (lower 8 bits of data byte offset)
|
||
Byte 3+: LED Color Data (variable length)
|
||
```
|
||
|
||
## LED Color Data
|
||
|
||
### RGB LEDs (3 bytes per LED)
|
||
|
||
```text
|
||
[R][G][B][R][G][B][R][G][B]...
|
||
```
|
||
|
||
### RGBW LEDs (4 bytes per LED)
|
||
|
||
```text
|
||
[R][G][B][W][R][G][B][W][R][G][B][W]...
|
||
```
|
||
|
||
All values are 0-255.
|
||
|
||
### Offset Calculation
|
||
|
||
The offset field specifies the starting byte position in the LED data buffer:
|
||
|
||
- **16-bit value**: Combines Offset High and Offset Low bytes (big-endian)
|
||
- **Range**: 0-65535 bytes supported
|
||
- **Purpose**: Allows partial updates of LED strip data at any byte position
|
||
|
||
**Example Calculations:**
|
||
|
||
- Byte position 0: `Offset High = 0x00, Offset Low = 0x00`
|
||
- Byte position 30: `Offset High = 0x00, Offset Low = 0x1E` (10 RGB LEDs × 3 bytes)
|
||
- Byte position 256: `Offset High = 0x01, Offset Low = 0x00`
|
||
- Byte position 1000: `Offset High = 0x03, Offset Low = 0xE8`
|
||
|
||
**LED Position to Byte Offset Conversion:**
|
||
|
||
- **RGB LEDs**: `byte_offset = led_position × 3`
|
||
- **RGBW LEDs**: `byte_offset = led_position × 4`
|
||
|
||
## LED Chip Specifications
|
||
|
||
### WS2812B (RGB)
|
||
|
||
- **Type**: RGB
|
||
- **Data Format**: 3 bytes per LED
|
||
- **Color Order**: G-R-B (Green, Red, Blue)
|
||
- **Voltage**: 5V
|
||
- **Protocol**: Single-wire serial
|
||
- **Timing**: 800kHz data rate
|
||
|
||
### SK6812 (RGB)
|
||
|
||
- **Type**: RGB
|
||
- **Data Format**: 3 bytes per LED
|
||
- **Color Order**: G-R-B (Green, Red, Blue)
|
||
- **Voltage**: 5V
|
||
- **Protocol**: Single-wire serial
|
||
- **Timing**: 800kHz data rate
|
||
- **Features**: Improved PWM linearity compared to WS2812B
|
||
|
||
### SK6812-RGBW
|
||
|
||
- **Type**: RGBW
|
||
- **Data Format**: 4 bytes per LED
|
||
- **Color Order**: G-R-B-W (Green, Red, Blue, White)
|
||
- **Voltage**: 5V
|
||
- **Protocol**: Single-wire serial
|
||
- **Timing**: 800kHz data rate
|
||
- **Features**: Dedicated white channel for better color mixing and higher brightness
|
||
|
||
## Color Calibration
|
||
|
||
Colors are calibrated before transmission:
|
||
|
||
**RGB:**
|
||
|
||
```rust
|
||
calibrated_r = (original_r * calibration_r) / 255
|
||
calibrated_g = (original_g * calibration_g) / 255
|
||
calibrated_b = (original_b * calibration_b) / 255
|
||
```
|
||
|
||
**RGBW:**
|
||
|
||
```rust
|
||
calibrated_r = (original_r * calibration_r) / 255
|
||
calibrated_g = (original_g * calibration_g) / 255
|
||
calibrated_b = (original_b * calibration_b) / 255
|
||
calibrated_w = calibration_w // Direct value
|
||
```
|
||
|
||
## Hardware Control Protocol (Hardware → Desktop)
|
||
|
||
### Display Brightness Control
|
||
|
||
Hardware can send display brightness adjustment commands to the desktop:
|
||
|
||
```text
|
||
Byte 0: Header (0x03)
|
||
Byte 1: Display Index (0-based display number)
|
||
Byte 2: Brightness (0-255, where 255 = 100% brightness)
|
||
```
|
||
|
||
**Example:** Set display 0 to 50% brightness
|
||
|
||
```text
|
||
03 00 80
|
||
│ │ └─ Brightness (128 = ~50%)
|
||
│ └─ Display Index (0)
|
||
└─ Header (0x03)
|
||
```
|
||
|
||
### Volume Control
|
||
|
||
Hardware can send system volume adjustment commands to the desktop:
|
||
|
||
```text
|
||
Byte 0: Header (0x04)
|
||
Byte 1: Volume Percent (0-100)
|
||
```
|
||
|
||
**Example:** Set system volume to 75%
|
||
|
||
```text
|
||
04 4B
|
||
│ └─ Volume (75%)
|
||
└─ Header (0x04)
|
||
```
|
||
|
||
## Connection State Management
|
||
|
||
### Connection States
|
||
|
||
- **Unknown**: Initial state when device is first discovered
|
||
- **Connecting**: Device is being tested, includes retry count (1-10)
|
||
- **Connected**: Device is responding to ping requests normally
|
||
- **Disconnected**: Device failed to respond after 10 retry attempts
|
||
|
||
### State Transitions
|
||
|
||
```text
|
||
Unknown → Connecting(1) → Connected
|
||
↓ ↓ ↓
|
||
↓ Connecting(2-10) ↓
|
||
↓ ↓ ↓
|
||
└─→ Disconnected ←────────┘
|
||
```
|
||
|
||
### Retry Logic
|
||
|
||
1. **Initial Connection**: When device discovered via mDNS
|
||
2. **Health Check Failure**: If ping timeout or wrong response
|
||
3. **Retry Attempts**: Up to 10 attempts with 1-second intervals
|
||
4. **Disconnection**: After 10 failed attempts, mark as disconnected
|
||
5. **Recovery**: Disconnected devices continue to receive ping attempts
|
||
|
||
## Packet Examples
|
||
|
||
### RGB Example
|
||
|
||
3 RGB LEDs starting at byte offset 0: Red, Green, Blue
|
||
|
||
```text
|
||
02 00 00 FF 00 00 00 FF 00 00 00 FF
|
||
│ │ │ └─────────────────────────── 9 bytes color data
|
||
│ │ └─ Offset Low (0 bytes)
|
||
│ └─ Offset High (0)
|
||
└─ Header (0x02)
|
||
```
|
||
|
||
### RGBW Example
|
||
|
||
2 RGBW LEDs starting at byte offset 40 (LED position 10): White, Warm White
|
||
|
||
```text
|
||
02 00 28 FF FF FF FF FF C8 96 C8
|
||
│ │ │ └─────────────────────── 8 bytes color data
|
||
│ │ └─ Offset Low (40 bytes = 0x28)
|
||
│ └─ Offset High (0)
|
||
└─ Header (0x02)
|
||
```
|
||
|
||
## Implementation Notes
|
||
|
||
- **Byte Order**: Big-endian for multi-byte values (offset field)
|
||
- **Delivery**: Fire-and-forget UDP (no acknowledgment required)
|
||
- **Hardware Role**: Simple UDP-to-LED bridge, no data processing
|
||
- **LED Type Logic**: Handled entirely on desktop side, not hardware
|
||
- **Mixed Types**: Same display can have both RGB and RGBW strips
|
||
- **Data Flow**: Desktop → UDP → Hardware → LED Strip (direct forward)
|
||
- **Color Order**: Hardware must handle color order conversion for different LED chips
|
||
- **LED Compatibility**: Supports WS2812B, SK6812, and SK6812-RGBW chips
|
||
|
||
## Hardware Implementation
|
||
|
||
The hardware board handles multiple protocol functions: UDP-to-WS2812 bridge for LED data, health monitoring, and optional control input capabilities.
|
||
|
||
### Required Functions
|
||
|
||
1. **mDNS Service Registration**: Advertise `_ambient_light._udp.local.` service
|
||
2. **UDP Server**: Listen on port 23042 for incoming packets
|
||
3. **Packet Processing**: Handle different message types based on header
|
||
4. **Health Monitoring**: Respond to ping requests with pong
|
||
5. **LED Control**: Forward color data to WS2812 strips
|
||
6. **Optional Control**: Send brightness/volume commands to desktop
|
||
|
||
### Packet Processing Logic
|
||
|
||
```c
|
||
void process_packet(uint8_t* data, size_t len) {
|
||
if (len < 1) return;
|
||
|
||
switch (data[0]) {
|
||
case 0x01: // Ping request
|
||
handle_ping(data, len);
|
||
break;
|
||
|
||
case 0x02: // LED color data
|
||
handle_led_data(data, len);
|
||
break;
|
||
|
||
default:
|
||
// Unknown packet type, ignore
|
||
break;
|
||
}
|
||
}
|
||
|
||
void handle_ping(uint8_t* data, size_t len) {
|
||
if (len != 1) return;
|
||
|
||
// Respond with pong
|
||
uint8_t pong = 0x01;
|
||
udp_send_response(&pong, 1);
|
||
}
|
||
|
||
void handle_led_data(uint8_t* data, size_t len) {
|
||
if (len < 3) return;
|
||
|
||
uint16_t byte_offset = (data[1] << 8) | data[2];
|
||
uint8_t* color_data = &data[3];
|
||
size_t color_len = len - 3;
|
||
|
||
// Direct forward to LED strip - supports WS2812B, SK6812, SK6812-RGBW
|
||
// byte_offset specifies the starting byte position in LED data buffer
|
||
// Color order conversion handled by LED driver library
|
||
led_strip_update(byte_offset, color_data, color_len);
|
||
}
|
||
```
|
||
|
||
### Optional Control Features
|
||
|
||
Hardware can optionally send control commands to desktop:
|
||
|
||
```c
|
||
// Send display brightness control
|
||
void send_brightness_control(uint8_t display_index, uint8_t brightness) {
|
||
uint8_t packet[3] = {0x03, display_index, brightness};
|
||
udp_send_to_desktop(packet, 3);
|
||
}
|
||
|
||
// Send volume control
|
||
void send_volume_control(uint8_t volume_percent) {
|
||
uint8_t packet[2] = {0x04, volume_percent};
|
||
udp_send_to_desktop(packet, 2);
|
||
}
|
||
```
|
||
|
||
### LED Strip Driver Implementation
|
||
|
||
For SK6812-RGBW support, hardware must handle the G-R-B-W color order:
|
||
|
||
```c
|
||
// Example LED strip update function for SK6812-RGBW
|
||
void led_strip_update(uint16_t offset, uint8_t* data, size_t len) {
|
||
// For SK6812-RGBW: data comes as [R][G][B][W] from desktop
|
||
// Must be reordered to [G][R][B][W] for the LED chip
|
||
|
||
size_t led_count = len / 4; // 4 bytes per RGBW LED
|
||
uint8_t* output_buffer = malloc(len);
|
||
|
||
for (size_t i = 0; i < led_count; i++) {
|
||
uint8_t r = data[i * 4 + 0];
|
||
uint8_t g = data[i * 4 + 1];
|
||
uint8_t b = data[i * 4 + 2];
|
||
uint8_t w = data[i * 4 + 3];
|
||
|
||
// Reorder to G-R-B-W for SK6812-RGBW
|
||
output_buffer[i * 4 + 0] = g; // Green first
|
||
output_buffer[i * 4 + 1] = r; // Red second
|
||
output_buffer[i * 4 + 2] = b; // Blue third
|
||
output_buffer[i * 4 + 3] = w; // White fourth
|
||
}
|
||
|
||
// Send to LED strip with proper timing
|
||
sk6812_rgbw_send(offset, output_buffer, len);
|
||
free(output_buffer);
|
||
}
|
||
```
|
||
|
||
### Key Implementation Notes
|
||
|
||
- **Ping Response**: Must respond to ping (0x01) within 1 second
|
||
- **LED Data**: Direct forward to LED strip, with color order conversion if needed
|
||
- **Color Order**: SK6812-RGBW requires G-R-B-W order, desktop sends R-G-B-W
|
||
- **Control Commands**: Optional feature for hardware with input capabilities
|
||
- **mDNS Registration**: Essential for automatic device discovery
|
||
- **UDP Server**: Must handle concurrent connections from multiple desktops
|
||
- **LED Chip Support**: Must support WS2812B (RGB), SK6812 (RGB), and SK6812-RGBW
|
||
|
||
## Troubleshooting
|
||
|
||
### Device Discovery Issues
|
||
|
||
**Device Not Found**:
|
||
|
||
- Verify mDNS service registration on hardware
|
||
- Check service type: `_ambient_light._udp.local.`
|
||
- Ensure port 23042 is accessible
|
||
- Verify network connectivity between desktop and hardware
|
||
|
||
**Device Shows as Disconnected**:
|
||
|
||
- Check ping/pong response implementation
|
||
- Verify hardware responds to 0x01 packets within 1 second
|
||
- Monitor network latency and packet loss
|
||
- Check UDP server implementation on hardware
|
||
|
||
### LED Control Issues
|
||
|
||
**No LED Updates**:
|
||
|
||
- Verify hardware processes 0x02 packets correctly
|
||
- Check WS2812 wiring and power supply
|
||
- Monitor packet reception on hardware side
|
||
- Verify byte offset calculations and LED strip configuration
|
||
|
||
**Wrong Colors**:
|
||
|
||
- Check color calibration settings on desktop
|
||
- Verify RGB/RGBW data format matches LED strip type
|
||
- Monitor color data in packets (bytes 3+)
|
||
- Check LED chip color order:
|
||
- WS2812B: G-R-B order
|
||
- SK6812: G-R-B order
|
||
- SK6812-RGBW: G-R-B-W order
|
||
- Ensure hardware converts R-G-B(-W) from desktop to correct chip order
|
||
|
||
**Flickering or Lag**:
|
||
|
||
- Monitor packet rate and network congestion
|
||
- Check power supply stability for LED strips
|
||
- Verify WS2812 data signal integrity
|
||
- Consider reducing update frequency
|
||
|
||
### Control Protocol Issues
|
||
|
||
**Brightness/Volume Control Not Working**:
|
||
|
||
- Verify hardware sends correct packet format (0x03/0x04)
|
||
- Check desktop receives and processes control packets
|
||
- Monitor packet transmission from hardware
|
||
- Verify display index and value ranges
|
||
|
||
### Connection State Issues
|
||
|
||
**Frequent Disconnections**:
|
||
|
||
- Check network stability and latency
|
||
- Verify ping response timing (< 1 second)
|
||
- Monitor retry logic and connection state transitions
|
||
- Check for UDP packet loss
|
||
|
||
**Stuck in Connecting State**:
|
||
|
||
- Verify ping/pong packet format
|
||
- Check hardware UDP server implementation
|
||
- Monitor ping response timing
|
||
- Verify network firewall settings
|
||
|
||
### Network Debugging
|
||
|
||
**Packet Monitoring**:
|
||
|
||
```bash
|
||
# Monitor UDP traffic on port 23042
|
||
tcpdump -i any -X port 23042
|
||
|
||
# Check mDNS service discovery
|
||
dns-sd -B _ambient_light._udp.local.
|
||
```
|
||
|
||
**Hardware Debug Output**:
|
||
|
||
- Log received packet headers and lengths
|
||
- Monitor ping/pong timing
|
||
- Track LED data processing
|
||
- Log mDNS service registration status
|
||
|
||
## Protocol Version
|
||
|
||
- **Current**: 1.0
|
||
- **Headers**: 0x01 (Ping/Pong), 0x02 (LED Data), 0x03 (Brightness), 0x04 (Volume)
|
||
- **Future**: Additional headers for new features, backward compatibility maintained
|